Performance Evaluation of Full Facepiece Respirators with Cartridges

Category: Control Techniques and Strategy

Volume: 17 | Issue: 5 | Pages: 1316-1328
DOI: 10.4209/aaqr.2016.11.0485
PDF | RIS | BibTeX

Shu-An Lee 1, Yen-Lung Chen1, Dong-Chir Hwang1, Chih-Chao Wu1, Jen-Kun Chen2,3

  • 1 Department of Environmental Engineering and Science, Feng Chia University, Taichung 40724, Taiwan
  • 2 Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli 35053, Taiwan
  • 3 Graduate Institute of Life Sciences, National Defense Medical Center, Taipei 11490, Taiwan

Highlights

Particle penetration in charcoal cartridges increased with increasing air intake.
DOP particles penetrated more than NaCl particles.
FFs rather than facial dimension significantly correlated with PFs.
Protection of FFRs against particles in nano-sized range might not be sufficient.


Abstract

Full facepiece respirators (FFRs) with charcoal cartridges are very common wearable devices for industrial or military purposes preventing respiratory tract, face, eyes, and mouth from hazards exposure. However, related research for performance evaluation was rare. We aimed to use a self-developed testing system investigating (1) filtration efficiency (FE) of aerosols in charcoal cartridges; (2) breakthrough time of cyclohexane in charcoal cartridges; (3) fit factors (FFs) and (4) protection factors (PFs) of FRRs. The results showed that FE of charcoal cartridges against 0.3 µm of sodium chloride (NaCl) and dioctyl phthalate (DOP) particles under 85 L min–1 were 99.93% and 99.89%, respectively, which did not meet the standard 99.97% regulated for filters such as P100 and HEPA. As for 42.5 L min–1 condition (dual canisters), the FE against NaCl (99.97%) did meet the requirement set for HEPA (99.97%); however, that against DOP (99.95%) failed to meet the standard. In addition, the breakthrough time of 3000ppm cyclohexane was 31 min under 32 L min–1, which was longer than the 30 min standard described in CNS6636 Z2023 and JIS8152. As to the results of fit test among 21 subjects, only 1 failed to meet the requirement (fit factor = 500) and the average of fit factors was 8342 ± 5892. The mean value of protection factors was 112.3 ± 54.6 while 3 users had lower PFs than the assigned protection factor (APF = 50) regulated by Occupational Safety and Health Administration (OSHA). APFs obtained for particles less than 100 nm were smaller than the APF standard regulated by OSHA, indicating APF standards may be overestimated for such particle size. Therefore, users should be aware of potential risks caused by such substances in nano-sized scale (e.g., nanoparticles or viruses) when wearing FFRs.

Keywords

Respirator Full mask Cartridge Filtration Protection Fit factor


Related Article

Improved Photocatalytic Air Cleaner with Decomposition of Aldehyde and Aerosol-Associated Influenza Virus Infectivity in Indoor Air

Kimiyasu Shiraki , Hiroshi Yamada, Yoshihiro Yoshida, Ayumu Ohno, Teruo Watanabe, Takafumi Watanabe, Hiroyuki Watanabe, Hidemitsu Watanabe, Masao Yamaguchi, Fumio Tokuoka, Shigeatsu Hashimoto, Masakazu Kawamura, Norihisa Adachi
Volume: 17 | Issue: 11 | Pages: 2901-2912
DOI: 10.4209/aaqr.2017.06.0220
PDF

High Selectivity of Visible-Light-Driven La-doped TiO2 Photocatalysts for NO Removal

Yu Huang, Jun-Ji Cao, Fei Kang, Sheng-Jie You, Chia-Wei Chang, Ya-Fen Wang
Volume: 17 | Issue: 10 | Pages: 2555-2565
DOI: 10.4209/aaqr.2017.08.0282
PDF
;