OPEN ACCESS

Articles online

Spectral Light Absorption of Ambient Aerosols in Urban Beijing during Summer: An Intercomparison of Measurements from a Range of Instruments

Category: Aerosol Physics and Instrumentation

Volume: 15 | Issue: 4 | Pages: 1178-1187
DOI: 10.4209/aaqr.2014.09.0224
PDF | Supplemental material | RIS | BibTeX

Yunfei Wu 1, Peng Yan2, Ping Tian1, Jun Tao3, Ling Li4, Jianmin Chen4, Yangmei Zhang5, Nianwen Cao6, Chong Chen6, Renjian Zhang 1

  • 1 RCE-TEA, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China
  • 2 CAWAS, Meteorological Observation Center of CMA, Beijing 100081, China
  • 3 South China Institute of Environmental Sciences, Ministry of Environmental Protection, Guangzhou 510655, China
  • 4 Center of Atmospheric Chemistry Study, Department of Environmental Science and Engineering, Fudan University, Shanghai 200433, China
  • 5 Chinese Academy of Meteorological Sciences of CMA, Beijing 100081, China
  • 6 School of Atmospheric Physics, Nanjing University of Information Science and Technology, Nanjing 210044, China

Highlights

Intercomparisons of the bap determined by different methods were performed.
The corrected bap of PSAP agreed well with the reference determined by the MAAP.
A new conversion factor between the bap and the BC recorded by AE-31 was presented.
The αap were interestedly lower than 1, especially during the pollution.


Abstract

Aerosol light absorption is important to radiation balance, but it is difficult to accurately quantify using measurements. An intercomparison experiment for the measurement of the aerosol absorption coefficient (bap) was performed at an urban site in Beijing during the summer of 2012, including the filter-based particle soot absorption photometer (PSAP) and aethalometer (AE-31), and the reference photoacoustic extinctiometer (PAX), CRDS-Neph (cavity-ring down spectroscopy/nephelometer) system, and multi-angle absorption photometer (MAAP). The CRDS-Neph system and PAX performed poorly due to unexpected reasons. The corrected bap of the PSAP agreed well with the reference values determined by the MAAP, implying the applicability of this correction scheme as well as the credibility of the reference bap of the MAAP. A new conversion factor with a value of ~7.1 ± 0.05 m2/g at ~530 nm was established by regressing the reference bap against the AE-31 recorded black carbon (BC) concentrations, which is lower than the previously used value (8.28 m2/g).

Accordingly, the absorption Ångström exponent (αap) was estimated as 0.85 ± 0.21 on average. It was ~1 on clean days but significantly lower during pollution episodes, implying the main contributor to aerosol light absorption is freshly-emitted BC on clean days but aged BC during pollution. BC core sizes and the coating are likely to have a great impact on the αap, which needs further investigation. The mass absorption efficiency of BC was estimated by regressing the bap against the filter-analyzed elemental carbon (EC) concentrations, resulting in a mean of 9.2 ± 0.5 m2/g at 670 nm. It was remarkably higher during pollution episodes than on clean days, implying a high variation of aerosol properties, such as the mixing state, with pollution levels.

Keywords

Ambient aerosol Black carbon Spectral light absorption


Related Article

Single-Particle Characterizations of Ambient Aerosols during a Wintertime Pollution Episode in Nanning: Local Emissions vs. Regional Transport

Tingting Xu, Hong Chen, Xiaohui Lu, Deborah S. Gross, Xin Yang , Zhaoyu Mo, Zhiming Chen, Huilin Liu, Jingying Mao, Guiyun Liang
Volume: 17 | Issue: 1 | Pages: 49-58
DOI: 10.4209/aaqr.2016.01.0026
PDF | Supplemental material

Characterization of Chemical and Microbial Species from Size-Segregated Indoor and Outdoor Particulate Samples

Olli Sippula , Helena Rintala, Mikko Happo, Pasi Jalava, Kari Kuuspalo, Annika Virén, Ari Leskinen, Ari Markkanen, Mika Komppula, Piia Markkanen, Kari Lehtinen, Jorma Jokiniemi, Maija-Riitta Hirvonen
Volume: 13 | Issue: 4 | Pages: 1212-1230
DOI: 10.4209/aaqr.2012.11.0300
PDF | Supplemental material

The Construction and Application of a Multipoint Sampling System for Vehicle Exhaust Plumes

Xianbao Shen, Zhiliang Yao , Kebin He , Xinyue Cao, Huan Liu
Volume: 17 | Issue: 7 | Pages: 1705-1716
DOI: 10.4209/aaqr.2017.02.0076
PDF

Performance Estimation of a Louver Dust Collector Attached to the Bottom of a Subway Train Running in a Tunnel

Jung-Bo Sim, Sang-Hee Woo, Won-Geun Kim, Se-Jin Yook , Jong Bum Kim, Gwi-Nam Bae, Hwa Hyun Yoon
Article In Press
DOI: 10.4209/aaqr.2017.01.0043
PDF
;