OPEN ACCESS

Articles online

Deposition Removal of Monodisperse and Polydisperse Submicron Particles by a Negative Air Ionizer

Category: Control Techniques and Strategy

Volume: 15 | Issue: 3 | Pages: 994-1007
DOI: 10.4209/aaqr.2014.08.0166
PDF | RIS | BibTeX

Yi-Ying Wu, Yen-Chi Chen, Kuo-Pin Yu , Yen-Ping Chen, Hui-Chi Shih

  • Institute of Environmental and Occupational Health Sciences, National Yang-Ming University, No.155, Li-Nong Street, Section 2, Taipei, Taiwan

Highlights

Air ionizer can enhance the submicron particle deposition rate up to 115 folds. 
Polydisperse coagulation considerably affects the measurement of deposition rate.
Theoretical model predicts the deposition rate of submicron particle in chamber well.


Abstract

Indoor particulate matter exposure is one of the main environmental risk factors influencing human health. Previous studies have indicated that the degree of hazards about ultrafine particles was associated with the particle surface area and number concentration. Polydisperse submicron particles (PSPs) contribute most of the indoor aerosol particle number and are usually used for removal testing. However, the behaviors of monodisperse submicron particles (MSPs) are easier to analyze. This study aims to investigate the difference between the deposition removal efficiency of MSP and PSP by the negative air ionizer (NAI) under different ssettings of freestream air velocity (FAV).

The particle-removal experiments were conducted in a stainless steel test chamber under the condition of 50% relative humidity and FAV of 0.56, 1.2 and 2.0 m/s. The NaCl and oleic acid PSPs were generated from a constant output atomizer and the NaCl MSPs (30, 50, 100, 170 and 300 nm) were generated by passing the polydisperse NaCl aerosol through a Differential Mobility Analyzer. The concentration and size distribution of the particles in the chamber were monitored with a Scanning Mobility Particle Sizer (SMPS). The decay constant of particles number concentration, particle removal efficiency (PRE), enhancement factor of deposition rate (EF) and air cleaner effectiveness (ACE) were determined from the SMPS data.

The decay constant of particle number concentration increased with the decrease of FAV and decreased with the increase of particle size. Both of the PREs of MSP and PSP were quite high, especially for the smaller particles and under low FAV. The EFs ranged from 4.4 to 115.5 and were proportional to the particle size. In addition, the ACE ranged from 0.57 to 0.96 and increased as the particle size increased. These results give a better understanding of the deposition of 30–300-nm particles enhanced by the NAI and the influential factors.

Keywords

Submicron particles Negative air ionizer Enhancement factor


Related Article

Preparation and Characteristic of Antibacterial Facemasks with Chinese Herbal Microcapsules

Ya-Fen Wang , Fei Kang, Sheng-Jie You, Cheng-Hsien Tsai, Geng-Le Lin
Accepted Manuscripts
DOI: 10.4209/aaqr.2017.06.0208
PDF

Ozone Catalytic Oxidation of Gaseous Toluene over MnO2-Based Ozone Decomposition Catalysts Immobilized on a Nonwoven Fabric

Kazuhiko Sekiguchi , Yuki Kurita, Kenshi Sankoda, Norikazu Namiki, Fumio Yasui, Hajime Tamura
Accepted Manuscripts
DOI: 10.4209/aaqr.2017.01.0045
PDF

Novel Method for Preparing Controllable Nanoporous α-Fe2O3 and its Reactivity to SCR De-NOx

Haibo Liu, Zexin Zhang, Qian Li, Tianhu Chen , Changai Zhang, Dong Chen, Chengzhu Zhu, Yang Jiang
Volume: 17 | Issue: 7 | Pages: 1898-1908
DOI: 10.4209/aaqr.2017.05.0188
PDF

Effects of Nutrient Availability on the Biomass Production and CO2 Fixation in a Flat Plate Photobioreactor

Chih Ming Su, Hsin Ta Hsueh, Chi Ming Tseng, Dah Tong Ray, Yun Hwei Shen, Hsin Chu
Volume: 17 | Issue: 7 | Pages: 1887-1897
DOI: 10.4209/aaqr.2016.09.0386
PDF | Supplemental material
;