OPEN ACCESS

Articles online

Validation and Characterization of Persistent Organic Pollutant Emissions from Stack Flue Gases of an Electric Arc Furnace by Using a Long-Term Sampling System (AMESA®)

Category: Articles

Volume: 14 | Issue: 1 | Pages: 185-196
DOI: 10.4209/aaqr.2013.09.0285
PDF | Supplemental material | RIS | BibTeX

Edward Ming-Yang Wu1, Lin-Chi Wang 2, Sheng-Lun Lin3,4, Guo-Ping Chang-Chien4,5

  • 1 Department of Civil and Ecological Engineering, I-Shou University, No.1, Sec. 1, Syuecheng Road, Dashu Township, Kaohsiung County, 840, Taiwan
  • 2 Department of Civil Engineering and Geomatics, Cheng Shiu University, 840, Chengching Road, Kaohsiung 833, Taiwan
  • 3 Center of General Education, Cheng Shiu University, 840, Chengching Road, Kaohsiung 833, Taiwan
  • 4 Super Micro Mass Research and Technology Center, Cheng Shiu University, No. 840 Chengcing Rd., Kaohsiung 833, Taiwan
  • 5 Department of Cosmetic and Fashion Styling, Cheng Shiu University, 840, Chengching Road, Kaohsiung 833, Taiwan

Abstract

A long-term sampling system, called the Adsorption Method for Sampling of Dioxins and Furans (AMESA), was used for long-term sampling (up to 168 hours) of an electric arc furnace (EAF) to obtain the representative flue gas samples. In order to have a comprehensive view of the emissions of persistent organic pollutants (POPs) from EAFs, six POPs, including polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs), polychlorinated diphenyl ethers (PCDEs), polybrominated dibenzo-p-dioxins and dibenzofurans (PBDD/Fs), polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs), were investigated. Tests showed the breakthroughs of PBDD/Fs and PBDEs are much larger (8.9%–43%), while the others are less than 3%. A significant increase in breakthrough with the increase in halogen numbers is observed, because highly halogen-substituted POPs tend to partition to the particulate-phase. Except for PCBs and PCDEs, whose percentages of the POPs in the rinses to the total POPs collected from the long-term samples (cartridges + rinses) are less than 7%, those of the other POPs are all greater than 30%. Therefore, the solvents from the rinses of the sampling probe and other components need to be combined with an XAD-2 cartridge for analyses. The PCBs and PBDEs are the most abundant pollutants in the stack flue gases of the EAF, and their mass concentrations are one to three orders higher than those of the other POPs. With regard to POPs with dioxin-like toxicity, the percentages of the contributed toxicities by PCDD/Fs, PCBs and PBBD/Fs are 87.1%, 11.7% and 1.2%. The close association that PBDEs and PBDD/Fs have with the concentrations and congener profiles is not present for PCDEs and PCDD/Fs, suggesting the need for further studies of the formation mechanisms of these analogues.

Keywords

PCDD/Fs PCDEs PBDEs PBDD/Fs AMESA


Related Article

Reduction of Persistent Organic Pollutant Emissions during Incinerator Start-up by Using Crude Waste Cooking Oil as an Alternative Fuel

Chia-Yang Chen, Wen-Jhy Lee, John Kennedy Mwangi , Lin-Chi Wang, Jhong-Lin Wu , Sheng-Lun Lin
Volume: 17 | Issue: 3 | Pages: 899-912
DOI: 10.4209/aaqr.2016.09.0394
PDF

Experimental Study on PCDD/Fs Adsorption onto Nano-Graphite

Wenwei Li, Xiaoqing Lin , Mingfeng Yu, Ishrat Mubeen, Alfons Buekens, Xiaodong Li
Volume: 16 | Issue: 12 | Pages: 3281-3289
DOI: 10.4209/aaqr.2016.08.0353
PDF

Critical Emissions from the Largest On-Road Transport Network in South Asia

Saroj Kumar Sahu , Gufran Beig, Neha Parkhi
Volume: 14 | Issue: 1 | Pages: 135-144
DOI: 10.4209/aaqr.2013.04.0137
PDF

Ambient Air Quality during Diwali Festival over Kolkata – A Mega-City in India

A. Chatterjee , C. Sarkar, A. Adak, U. Mukherjee, S.K. Ghosh, S. Raha
Volume: 13 | Issue: 3 | Pages: 1133-1144
DOI: 10.4209/aaqr.2012.03.0062
PDF
;