OPEN ACCESS

Articles online

PCDD/F and PCBz Emissions during Start-up and Normal Operation of a Hazardous Waste Incinerator in China

Category: Articles

Volume: 14 | Issue: 4 | Pages: 1142-1151
DOI: 10.4209/aaqr.2013.03.0068
PDF | RIS | BibTeX

Xiaoqing Lin1, Qunxing Huang 1, Tong Chen1, Xiaodong Li1, Shengyong Lu1, Hailong Wu2, Jianhua Yan1, Miaosheng Zhou3, Hua Wang3

  • 1 State Key Laboratory of Clean Energy Utilization, Institute for Thermal Power Engineering, Zhejiang University, Hangzhou, Zhejiang Province 310027, China
  • 2 Environment Protection Bureau of Zhoushan, Zhoushan, Zhejiang province 316021, China
  • 3 Hangzhou Lijia Environmental Service Co., Ltd, Hangzhou, Zhejiang Province 311101, China

Abstract

The PCDD/F emissions from incinerator start-up are a major contributor to the total amount of such emissions, as has been reported in studies of numerous municipal solid waste incinerators. However, very few studies have examined the start-up process at hazardous waste incinerators (HWIs). In this work we studied the emissions of PCDD/Fs and other pollutants, such as PCBz, at the stack during start-up and normal operations in a HWI. We found that the PCDD/F emissions during start-up were greater than during normal operations, and were comparable to the annual emissions during the normal combustion regime. The emissions of PCDD/Fs were highest during start-up when the temperature was around 500°C, reaching 59.5 ng/Nm3 (5.49 ng I-TEQ/Nm3) when no APCDs were applied. The emission values of PCDD/Fs during start-up with the application of APCDs and during normal operations were very low, which indicates the importance of APCDs when starting up a HWI, as well as before feeding waste. The chlorination degree, the ratio of PCDFs/PCDDs and the congener profiles were also discussed during start-up and normal operations, with the results suggesting different formation mechanisms of PCDD/Fs. PCBz emissions are two or three orders of magnitude higher than those of PCDD/Fs, and 1,2,4,5-TeCBz was the best correlated PCBz used as a PCDD/F indicator in real HWI flue gas.

Keywords

Start-up Hazardous waste incinerator PCDD/Fs PCBz


Related Article

Atmospheric Deposition of Polychlorinated Dibenzo-p-Dioxins and Dibenzofurans in Two Cities of Southern China

Jinning Zhu, Haiyan Tang, Jin Xing, Wen-Jhy Lee , Ping Yan , Kangping Cui
Volume: 17 | Issue: 7 | Pages: 1798-1810
DOI: 10.4209/aaqr.2017.05.0177
PDF

Part I: PM2.5 and Polychlorinated Dibenzo-p-dioxins and Dibenzofurans (PCDD/Fs) in the Ambient Air of Southern China

Haiyan Tang, Kangping Cui , Jin Xing, Jinning Zhu , Wen-Jhy Lee, John Kennedy Mwangi, Yu-Cheng Lee
Volume: 17 | Issue: 6 | Pages: 1550-1569
DOI: 10.4209/aaqr.2017.03.0117
PDF

Critical Emissions from the Largest On-Road Transport Network in South Asia

Saroj Kumar Sahu , Gufran Beig, Neha Parkhi
Volume: 14 | Issue: 1 | Pages: 135-144
DOI: 10.4209/aaqr.2013.04.0137
PDF

Ambient Air Quality during Diwali Festival over Kolkata – A Mega-City in India

A. Chatterjee , C. Sarkar, A. Adak, U. Mukherjee, S.K. Ghosh, S. Raha
Volume: 13 | Issue: 3 | Pages: 1133-1144
DOI: 10.4209/aaqr.2012.03.0062
PDF
;