OPEN ACCESS

Articles online

Fate and Distribution of Polychlorinated Dibenzo-p-dioxins and Dibenzofurans in a Woodchip-fuelled Boiler

Category: Articles

Volume: 11 | Issue: 3 | Pages: 282-289
DOI: 10.4209/aaqr.2010.11.0098
PDF | RIS | BibTeX

Wei-Sheng Chen1,2, Yun-Hwei Shen 1, Ting-Yu Hsieh2,3, Chang-Wen Lin2, Lin-Chi Wang 4,5, Guo-Ping Chang-Chien4,5

  • 1 Department of Resources Engineering, National Cheng Kung University, 1, University Road, Tainan 70101, Taiwan, R.O.C.
  • 2 Sustainable Environment Research Center, National Cheng Kung University, 1, University Road, Tainan 70101, Taiwan, R.O.C.
  • 3 Department of Environmental Engineering, National Cheng Kung University, 1, University Road, Tainan 70101, Taiwan, R.O.C.
  • 4 Department of Chemical and Materials Engineering, Cheng Shiu University, 840, Chengching Road, Kaohsiung 833, Taiwan, R.O.C.
  • 5 Super Micro Mass Research and Technology Center, Cheng Shiu University, 840, Chengching Road, Kaohsiung 833, Taiwan, R.O.C.

Abstract

As yet, very little is known about the PCDD/F fate and distribution in the woodchip-fuelled boilers. In this study, the feeding woodchips, stack flue gases and the ashes in different units of a woodchip-fuelled boiler are sampled to investigate their PCDD/F characteristics. The PCDD/F contents in the bottom residues and fly ashes ranged from 18.9 to 66.3 ng I-TEQ/kg, which are below the Taiwanese PCDD/F regulation for reutilization of bottom residues, but still higher than PCDD/F limitations on soils for agricultural use (10 ng I-TEQ/kg), which are adopted by several countries. From the PCDD/F output/input ratios, we found that combustion of woodchips in the boiler system is more favourable for the formations of PCDFs by de novo syntheses, especially for lower chlorinated PCDF congeners. Although about half of the input PCDD/Fs mass are destroyed in the combustion, the output PCDD/Fs toxicity are 6.9 times higher than the inputs. Fly ashes exhibited the highest PCDD/F distributions among the woodchip-fuelled boiler. Still 21.4% of total PCDD/F mass and 18.0% of total PCDD/F toxicity were emitted from the stack flue gases due to the lack of control devices for gaseous phase PCDD/Fs. Decreasing de novo syntheses among the boiler systems, deploying control devices for gaseous phase PCDD/Fs, and proper management on the reutilization of fly ashes will ensure woodchip-fuelled boilers as a sustainable and renewable biomass energy.

Keywords

Dioxin Wood Boiler Ash Stack flue gases


Related Article

Critical Emissions from the Largest On-Road Transport Network in South Asia

Saroj Kumar Sahu , Gufran Beig, Neha Parkhi
Volume: 14 | Issue: 1 | Pages: 135-144
DOI: 10.4209/aaqr.2013.04.0137
PDF

Ambient Air Quality during Diwali Festival over Kolkata – A Mega-City in India

A. Chatterjee , C. Sarkar, A. Adak, U. Mukherjee, S.K. Ghosh, S. Raha
Volume: 13 | Issue: 3 | Pages: 1133-1144
DOI: 10.4209/aaqr.2012.03.0062
PDF

Exploring the Variation between EC and BC in a Variety of Locations

Gbenga Oladoyin Salako, Philip K. Hopke , David D. Cohen, Bilkis A. Begum, Swapan K. Biswas, Gauri Girish Pandit, Yong-Sam Chung, Shamsiah Abd Rahman, Mohd Suhaimi Hamzah, Perry Davy, Andreas Markwitz, Dagva Shagjjamba, Sereeter Lodoysamba, Wanna Wimolwattanapun, Supamatthree Bunprapob
Volume: 12 | Issue: 1 | Pages: 1-7
DOI: 10.4209/aaqr.2011.09.0150
PDF
;