OPEN ACCESS

Articles online

A CFD Simulation Study of VOC and Formaldehyde Indoor Air Pollution Dispersion in an Apartment as Part of an Indoor Pollution Management Plan

Category: Articles

Volume: 11 | Issue: 6 | Pages: 758-762
DOI: 10.4209/aaqr.2010.11.0092
PDF | RIS | BibTeX

Ioannis K. Panagopoulos 1, Athanasios N. Karayannis1, Pavlos Kassomenos2, Kostantinos Aravossis3

  • 1 Sybilla ltd., 16 Ypsilandou st., Maroussi 151 22, Athens, Greece
  • 2 Department of Physics, University of Ioannina, University Campus 45 110, Ioannina, Greece
  • 3 Sector of Industrial Engineering and Operational Research, School of Mechanical Engineering, National Technical University of Athens, Polytechnioupolis, Zografos 174 54, Athens, Greece

Abstract

This paper is a preliminary report of an indoor pollution case study in a complex of apartments as a part of an Indoor Pollution Management Plan (IPMP). It describes the calculation by Computational Fluid Dynamics (CFD) techniques and presents the predicted air flow, Volatile Organic Compounds (VOCs) and formaldehyde contaminant distributions in an apartment comprised of a full-scale kitchen with open access to a living room, ventilated by an exhaust hood. The CFD Code PHOENICS®, which is based on solving the full 3-D Navier Stokes equations for turbulent flow and scalar conservation equations, was used. Major kitchen indoor pollution sources, VOCs and formaldehyde emitting materials and their emission characteristics were calculated through the use of emission factors. A typical apartment was used under case study and its detailed geometry was applied for the CFD model. To analyze the characteristics of the indoor environment, different mixing ventilation schemes (different locations of the cooker/oven and air inlets) were chosen as the parameters to investigate the indoor environment. The fields of VOCs and formaldehyde for several air inlets window positions, and ventilation parameters were calculated and compared. It was concluded that CFD methods can be used as a useful tool to assist the rational design of indoor spaces.

Keywords

CDF Indoor air pollution Numerical modelling Turbulence Indoor sources


Related Article

Critical Emissions from the Largest On-Road Transport Network in South Asia

Saroj Kumar Sahu , Gufran Beig, Neha Parkhi
Volume: 14 | Issue: 1 | Pages: 135-144
DOI: 10.4209/aaqr.2013.04.0137
PDF

Ambient Air Quality during Diwali Festival over Kolkata – A Mega-City in India

A. Chatterjee , C. Sarkar, A. Adak, U. Mukherjee, S.K. Ghosh, S. Raha
Volume: 13 | Issue: 3 | Pages: 1133-1144
DOI: 10.4209/aaqr.2012.03.0062
PDF

Exploring the Variation between EC and BC in a Variety of Locations

Gbenga Oladoyin Salako, Philip K. Hopke , David D. Cohen, Bilkis A. Begum, Swapan K. Biswas, Gauri Girish Pandit, Yong-Sam Chung, Shamsiah Abd Rahman, Mohd Suhaimi Hamzah, Perry Davy, Andreas Markwitz, Dagva Shagjjamba, Sereeter Lodoysamba, Wanna Wimolwattanapun, Supamatthree Bunprapob
Volume: 12 | Issue: 1 | Pages: 1-7
DOI: 10.4209/aaqr.2011.09.0150
PDF
;