Particles Removal by Negative ionic Air Purifier in Cleanroom

Category: Articles

Volume: 11 | Issue: 2 | Pages: 179-186
DOI: 10.4209/aaqr.2010.06.0048
PDF | RIS | BibTeX

Angus Shiue1, Shih-Cheng Hu 2, Mao-Lin Tu3

  • 1 Graduate Institute of Mechanical and Electrical Engineering, National Taipei University of Technology, Taipei, Taiwan
  • 2 Department of Energy and Refrigerating Air-Conditioning Engineering, National Taipei University of Technology, Taipei, Taiwan
  • 3 General Education Center, Chienkuo Technology University, Chung-Hua, Taiwan

Abstract

This study investigated effectiveness of negative ionic air purifier in lowering the concentration of particles in a closed test chamber. The performance test was carried out in a closed test chamber under natural decay, as well as with an air mixing mechanism. Compared with natural decay, the air mixing mechanism could reduce particles concentration better (under the flow field condition). However, air change rate effect is limited in super cleanrooms that require suitable approaches to enhance control of particles concentration and to raise the effective cleaning rate of negative ionic air purifier. This study investigated the concentration gradient of particles at various heights and distances from the source of negative ions. Experiment results indicate that performance near the negative ionic purifier was better than in the rest of the cleanroom. In terms of height, the highest removal efficiency was observed at a height of 60 cm from the floor; it decreased substantially with increase in height. The empirical curves fit based for the concentration gradient of NAI generated was developed for estimating the NAI concentration at different heights and distances from the source of negative ionic air cleaner.

Keywords

Particle Negative air ion Air mixing Removal efficiency Air cleaning factor


Related Article

Critical Emissions from the Largest On-Road Transport Network in South Asia

Saroj Kumar Sahu , Gufran Beig, Neha Parkhi
Volume: 14 | Issue: 1 | Pages: 135-144
DOI: 10.4209/aaqr.2013.04.0137
PDF

Ambient Air Quality during Diwali Festival over Kolkata – A Mega-City in India

A. Chatterjee , C. Sarkar, A. Adak, U. Mukherjee, S.K. Ghosh, S. Raha
Volume: 13 | Issue: 3 | Pages: 1133-1144
DOI: 10.4209/aaqr.2012.03.0062
PDF

Exploring the Variation between EC and BC in a Variety of Locations

Gbenga Oladoyin Salako, Philip K. Hopke , David D. Cohen, Bilkis A. Begum, Swapan K. Biswas, Gauri Girish Pandit, Yong-Sam Chung, Shamsiah Abd Rahman, Mohd Suhaimi Hamzah, Perry Davy, Andreas Markwitz, Dagva Shagjjamba, Sereeter Lodoysamba, Wanna Wimolwattanapun, Supamatthree Bunprapob
Volume: 12 | Issue: 1 | Pages: 1-7
DOI: 10.4209/aaqr.2011.09.0150
PDF
;