OPEN ACCESS

Articles online

Dynamic Analysis on Particle Concentration Induced by Opening the Door of a Front Opening Unified Pod (FOUP) That Loaded with 25 Pieces of 300 mm Wafer Manufacturing Processes

Category: Articles

Volume: 9 | Issue: 1 | Pages: 139-148
DOI: 10.4209/aaqr.2008.11.0057
PDF | RIS | BibTeX

Shih-Cheng Hu 1, Chen-Wei Ku1, Yang-Cheng Shih1, Kwen Hsu2

  • 1 Department of Energy and Refrigerating Air-Conditioning Engineering, National Taipei University of Technology, Taipei, Taiwan
  • 2 TRW Company, Detroit Michigan, USA

Abstract

This study investigates experimentally and numerically the influences of FOUP door opening speed (Vdoor) and the pressure difference (dP) on the dynamic distributions of the averaged non-dimensional particle concentration in the FOUP (Cave), which is defined as averaged particle concentration in the FOUP (cave) divided by the particle concentration in the clean room (cCR). Here dP is the difference between the mini-environment pressure and the clean-room pressure. Results show that when Vdoor lies between 0.05 m/s~0.15 m/s and dP within 0.3 Pa-12.7 Pa, Cave proportional to 1/2ρVdoor2 and inversely proportional to dP. This can be expressed by a stepwise multiple regression equation: Cave = 4.56 × 10-1 (1/2ρVdoor2) – 4.6 × 10-4 dP + 4.96 × 10-3.

Keywords

FOUP Minienvironment Clean room Semiconductor processes


Related Article

Critical Emissions from the Largest On-Road Transport Network in South Asia

Saroj Kumar Sahu , Gufran Beig, Neha Parkhi
Volume: 14 | Issue: 1 | Pages: 135-144
DOI: 10.4209/aaqr.2013.04.0137
PDF

Ambient Air Quality during Diwali Festival over Kolkata – A Mega-City in India

A. Chatterjee , C. Sarkar, A. Adak, U. Mukherjee, S.K. Ghosh, S. Raha
Volume: 13 | Issue: 3 | Pages: 1133-1144
DOI: 10.4209/aaqr.2012.03.0062
PDF