About AAQR

Aims and Scope

Articles online
For contributors
Call for Papers
Guideline for the
Special Issue Proposal
Subscription
Information

Advertising

Contact Us
 
Search for  in   Search  Advanced search  

 

Volume 17, No. 1, January 2017, Pages 198-208 PDF(689 KB)  Supplementary MaterialPDFPDF (226 KB)
doi: 10.4209/aaqr.2016.09.0400   

Fluorescent Bioaerosol Particles Resulting from Human Occupancy with and without Respirators

Caijia Xu1, Chang-Yu Wu2, Maosheng Yao1

1 State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
2 Department of Environmental Engineering Sciences, Engineering School of Sustainable Infrastructure and Environment, University of Florida, Gainesville, FL 32611, USA

 

Highlights
  • Breath-borne bioaerosols of 1.93 ± 1.83 × 105 particles m–3 were shown to peak at 1.5 µm.
  • An average emission rate of 8.4 × 105 fluorescent particles person–1 hour–1 was observed.
  • Bioaerosol emission from exhaled breath accounted for about 17% increase in studied room.
  • Bioaerosol shielding efficiencies from human breath by respirator depend on the facial fit.

Abstract

 

Airborne transmission of pathogenic aerosols via human breath plays a major role in infectious disease outbreaks in indoor environments. Yet, their bioaerosol emission profiles are still not well quantified. Here, we first studied bioaerosol emission rates of human exhaled breath from 12 healthy subjects, and then evaluated the bioaerosol emissions when wearing two different respirators “Doctor masks” and N95 in a controlled environment (27 m3) using a bioaerosol sensor-ultraviolet aerodynamic particle spectrometer (UV-APS). The human bioaerosol contribution was further confirmed through classroom observation. The results showed that there was a peak around 1.5 µm for the fluorescent particles emitted from humans’ breath. For the controlled environment, the presence of 5 people without wearing masks increased bioaerosol concentration by 107% within 30 min at an average emission rate of 8.4 × 105 fluorescent particles person–1 hour–1 resulting from the occupancy. When wearing N95 masks or “Doctor masks”, bioaerosol increases were observed to be 81% or 31% for the controlled environment, respectively, lower compared to those without masks. In-classroom observation also showed a fluorescent particle concentration increase of about 50%. In all experiments, we observed a decline in PM number concentration. Bioaerosol emission from exhaled breath was calculated to account for about 17% of the increase in the controlled environment. The results here suggest the need for re-evaluating microbial aerosol exposure risks for medical sites that demand high levels of hygiene even while wearing a respirator.

 

 

Keywords: Bioaerosols; Exhaled breath; Respiratory masks; Shielding efficiencies; Controlled environment.

 

 

Copyright © 2009-2014 AAQR All right reserved.