About AAQR

Aims and Scope

Articles online
For contributors
Call for Papers
Guideline for the
Special Issue Proposal
Subscription
Information

Advertising

Contact Us
 
Search for  in   Search  Advanced search  

 

Volume 13, No. 3, June 2013, Pages 922-931 PDF(971 KB)  
doi: 10.4209/aaqr.2013.01.0009   

In Situ Rapid Evaluation of Indoor Bioaerosols Using an ATP Bioluminescence Assay

Chien-Jung Lin1, Yi-Tun Wang1, Kuo-Jung Hsien2, Ying I. Tsai1, Pei-Yi Kung1, Jih-Ming Chyan1

1 Department of Environmental Resources Management, Chia Nan University of Pharmacy and Science, 60, Sec. 1, Erren Rd., Rende, Tainan 71710, Taiwan
2 Department of Environmental Engineering and Science, Chia Nan University of Pharmacy and Science, 60, Sec. 1, Erren Rd., Rende, Tainan 71710, Taiwan

 

Abstract

 

An adenosine-5’-triphosphate (ATP) bioluminescence method was developed for detecting microbial activity in indoor air. This method was compared with the traditional method of collecting, culturing and counting CFUs. A comparison of the results showed that ATP bioluminescence, expressed as RLUs, was moderately correlated with the entire set of CFU counts (r = 0.607), and that the correlation improved to r = 0.963 (p value < 0.001) when CFU outliers were removed from the calculations. The ATP bioluminescence method was applied at four different sites; a hospital Chinese medicine diagnostic room, a library, a government office, and a railway station lobby. The results showed that microbial activity was far higher in the railway station lobby than at the other three sites, and this is believed to be due to the higher volume and density of people in this space. At all four sites, higher microbial activity was linked to indoor plants, garbage cans, shoe racks, and furnished waiting areas. PCA of the data showed that microbial activity in the Chinese medicine diagnostic room was closely related to room temperature and humidity, and hence lowering the latter can reduce the potential for microbial activity at this site. At all four sites, no correlation was found between microbial activity and airborne pollutants. The ATP bioluminescence method was applied for the rapid evaluation of room disinfection using chloride dioxide, and results showed that twenty minutes after spraying with 100 ppm ClO2, microbial activity was reduced to 38.7% of its original level. ATP bioluminescence is simpler, easier to operate, and more cost-effective than the conventional microbial culture method of evaluating microbial load. The results obtained in this research confirm that the proposed ATP bioluminescence technique is capable of instantaneously detecting microbial activity in an indoor environment. Moreover, this approach can be used for on-line evaluation of room disinfection efficiency.

 

 

Keywords: ATP bioluminescence; Bioaerosol; Microbial activity; Relative light unit; Principal component analysis; Indoor air quality.

 

 

Copyright © 2009-2014 AAQR All right reserved.